Features |
| |
Microprocessor based design.
Auto - calibration function.
Auto - Temp. compensation.
High accuracy & stability,Low drift and quick response.
Membrane key board for dust and water splash proof.
|
PHC-200 / PHC-201
|
|
|
Specification |
|
Model :
PHC-200
| Range: |
pH
0.00 ~ 14.00 pH / mV -1999 ~ +19999 mV / Temp. -10 ~ +100℃
|
|
Resolution:0.01pH,1mv,0.1℃ |
| Accuracy(Tamb=25℃): |
±0.01pH,±1mv,±1℃,(+1
digit)
|
Temp.
Compensation:Manual
0 ~ +100℃
Calibration:Single
or dual point
Slope Control:Manual
Display:0.5"
digital LCD display , with function directing
Auto-Check Functions:Low
battery alarm.
Input Connector:Standard
BNC connector.
Input Impedance:Greater
then 1012
Ω |
| Power: |
One
9V 006P Battery.(IEC
6F 22),Battery
Life : Approx.250 Hours. |
|
Power : one 006p 9V battery |
| Dimensions
/ Weight: |
180×80×35mm.
Approx. 250 gms.(※Meter only)
|
| |
Model :PHC-201
| Range: |
pH
0.00 ~ 14.00 pH / mV -1999 ~ +1999 mV / Temp -10 ~ +100℃
|
|
Resolution:0.01pH,1mv,0.1℃ |
| Accuracy(Tamb=25℃): |
±0.01pH,±1mv,±1℃,(+1
digit)
|
Temp.
Compensation:Manual
& Auto(0
~ +100℃)
Calibration:Automatic
Slope Control:Automatic |
| Display: |
TWIN
digital LCD display for pH-Temp. or mV-Temp. reading in the
meantime without switching, and multi-function directing. |
| Auto-Check Functions: |
Low
battery alarm. "E--1" Electrode deviation from ZERO
point.
"E--2" Electrode deviation from SLOPE point. |
Input
Connector:Standard
BNC connector.
Input Impedance:Greater
then 1012
Ω |
| Power: |
One
9V 006P Battery.(IEC
6F 22),Battery
Life : Approx.250 Hours. |
|
Power : one 006p 9V battery |
| Dimensions
/ Weight: |
180×80×35㎜.
Approx. 250 gms.(※Meter only)
|
|
|
|
| (B) PH PEN |
|
Features
|
| |
It is equipped with 7.0 buffer solution for calibration.
Extened Probe.
|
|
Specifications |
| |
Range:0 ~ 14.0 pH.
Resolution:0.1 pH.
Accuracy:±0.2 pH.
Power:One 9V 006P Battery.
Dimensions:158(L)×40(W)×34(D)㎜ |
|
|
|
|
|
|
(C)
Conductivity Meter
|
| |
Features |
|
Microprocessor based design.
High Stability , Low drift.
Auto - Calibration , Auto range lock , Auto Temp. compensation.
Membrane key board for dust and splash proof.
Cell constant adjust able from 0.005 to 1.500. |
| |
Specifications |
|
| Range: |
Conductivity 0 ~20.00 μs/cm,0 ~ 200.0 μs/cm,
0 ~2.000 ms/cm,0 ~ 20.00
ms/cm,Temperature 0 ~ 100℃ |
Auto Range:latch relay switch for auto range Connect Resistance<0.1Ω
Resolution:conductivity : 0.01/μs/cm,Temperature : 0.1℃
Accuracy(Tamb=25℃):conductivity : ±1﹪F.S. Temperature : ±0.3℃
Temp. Compensation:0 ~ 100℃ Automatic compensation.
Cell:three-element gold electrodes, built-in ATC sensor. |
| Display: |
TWIN digital LCD display for conductivity and temperature reading in the mean-time , with multi-function directing. |
Ambient / Operating Temperature:0 ~ 50℃(32 ~122℉)
Power:One 9V 006P Battery(IEC 6F 22), Battery Life : Approx.250Hours.
Dimensions / Weight:180×80×35㎜. Approx. 250
gms.(※Meter only) |
|
|
|
|
|
(D)
PH / ORP and conductivity controllers
|
| |
Specifications |
|
| Model:P.H / ORP-101 & P.H / ORP-102 |
Range:0 to 14pH , -1999 to +1999mV
Resolution:0.01pH ,1mV
Accuracy(Tamb=25℃):0.01pH , ±1 digit , 1mV ±1 digit
Temp. Compensation:Auto(ATC probe)or Manual
Ambient Temp.:0 to +60℃
Display:3½ , 0.8" LCD digital display with function indicator
Signal Output:DC 4 to 20mA , Max. Load 1 kΩ
Control Action:ON / OFF
Set Point:Hi / Lo
& Hi-Hi / Lo-Lo
Impedance:>1012
Ω
Power:110V , 220VAC ±12﹪, 50 /60 HZ
Cut Out Dimension:135(H)㎜×135(W)㎜×183(D)㎜
Weights:1.45Kg
|
P.H / ORP-101 & P.H / ORP-102 |
Model:EC-106
& RC-107
Range:0 to 20000μs/cm
& 0 to 20.00MΩ-㎝
Resolution:0.01/μs/cm
& 0.01 MΩ-㎝
Accuracy(Tamb=25℃):±2.0﹪
F.S.
Temp. Compensation:Auto(ATC probe)0 to 100℃
Ambient Temp.:0 to +60℃
Display:3½ , 0.8" LCD digital display with function indicator
Signal Output:DC 4 to 20mA , Max. Load 1 kΩ
Control Action:ON / OFF
Set Point:Hi / Lo
Impedance:>1012 Ω
Power:110V , 220VAC ±12﹪, 50 /60 HZ
Cut Out Dimension:135(H)㎜×135(W)㎜×183(D)㎜
Weights:1.45Kg |
|
|
|
|
|

|
|
|